Accessories
Signal-Processing Modules
When signal-processing output modules are
installed into the Power Vector's last
two module bays, they automatically insert
themselves into the mix bus signal path lead-
ing to the power amplifier stage. When two of
these output modules are installed, their ef-
fects are cascaded with the second to last
bay's module processing the signal first and
then passing it to the module in the last bay.
Two benefits are gained by this innovation: (1)
the effects insert jacks are still available for
use by external processing equipment, (2) the
signal-processing output modules act on the
raw mix bus signal before any other user con-
trols, like master volume, bass, and treble.
This then ensures that signal level dependent
processors, such as the CMP1R Compressor/
Limiter and the ANS1R Ambient
Noise
Sensor modules, perform as intended
regard-
less of front panel master control changes.
Remote Volume Control
The master volume control is motorized.
By using a motor to physically move the con-
trol knob, a new level of remote control
adjustability is achieved.
Regardless of where the master volume con-
trol is set on the amplifier, the remote can
move it up or down. Since the remote control
signal is now the drive signal to the motor,
noise on the remote control leads cannot mix
in with the amplifier signals. This gives the
Power Vector a fully functional and clean way
of remotely controlling overall system level.
Traditionally, remote volume control was ac-
complished by having the remote control
vary an analog control signal to an opto-
resistor in the amplifier. This opto-resistor
would further attenuate the signal level in the
amplifier, based on the remote control setting.
This approach has two drawbacks: (1) the
maximum volume that can be achieved by
changing the remote control was limited by
the master volume control setting on the
amplifier, or vice-versa depending on how
the amplifier was designed, the remote
could lower volume, but could not further in-
crease it; (2) the control signal, because it is
analog, is vulnerable to noise. If a 60 Hz
hum was picked up by the long remote
volume leads, it could cause the opto-
resistor to modulate the volume level at the
hum frequency.
PVSC
Power Vector
Security Cover
RVCP
Remote Volume
Control Panel
RPK87
Rack
Mounting Kit
PVMC
Module
Security
Cover
Power Vector Modular Amplifiers
V35, V60, V100, V150, V250
Bogen's Power Vector modular input amplifier series offers a wide range of
power levels from which to choose, with five models ranging from 35W to 250W.
The amplifiers are designed to work with both high- (70V/25V) and low- (4/8-ohm)
impedance speaker systems. Each model includes eight module bays for input
modules and allows up to four levels of priority between modules. Two module bays
are also capable of accepting signal-processing output modules. Each input channel
has an associated signal/clip LED for signal status. An 11-segment LED output meter
monitors output signal level, which can be controlled by the Remote Volume
Control Panel (RVCP, sold separately). Modules required, but sold separately.
WALL-MOUNTABLE
version
on Page 40
MIXER
version
on Page 48
Product Features:
5 models ranging from 35W to 250W, each
with a large power reserve
Capable of handling 70V, 25V, 8-ohm,
and 4-ohm speaker loads
8 input module bays (modules sold
separately)
Wide selection of advanced input modules
2 module bays capable of handling signal-
processing output modules
4 levels of priority between modules
11-segment LED output level meter with
Average and Peak switch
Motorized master volume control that can
be remotely operated (requires RVCP)
Bass and treble controls
Two-color LED for each channel indicates
signal active/signal clipping
Lockable switch permits user to select
either transformer-coupled outputs or
a direct low-impedance output
Master mute control mutes all audio from
the mixer section of the amplifier
Bass and treble control bypass switch
125 Hz Low Cut feature
2 rack spaces high (3-1/2")
Listed to UL Standard 60065
for US and Canada
Signal-processing insert jacks allow exter-
nal equipment to be inserted between the
pre-amp output and the power amp input
Pre-EQ unbalanced buffer output signal
“post” all unit controls, but “pre” any exter-
nal signal-processing equipment connected
Grounded, unswitched AC convenience
receptacle with a 500W maximum capacity
provided for external equipment
Security cover to protect volume, bass, and
treble controls (PVSC, sold separately)
Module security cover prevents tampering
with module controls (PVMC, 8 included)
Rack mountable (mounting kit RPK87,
sold separately)
Technical Specifications, Dimensions,
and Weights can be found on Page 79
ALL MODULES
SOLD SEPARATELY
Input & Signal
Processing Modules-
See Pages 39 & 40
MODULES
www.bogen.com
38
AMPLIFIERS
MODULAR AMPLIFIERS
Rear View
Seitenansicht 0
1 2 3 4 5 6 ... 12 13

Inhaltsverzeichnis

Seite 1 - MODULAR AMPLIFIERS

AccessoriesSignal-Processing ModulesWhen signal-processing output modules areinstalled into the Power Vector's lasttwo module bays, they automati

Seite 2 - ADVANCED INPUT MODULES

AccessoriesWhat Does The Pro-Matrix Do?The Pro-Matrix Amplifier is ideally suitedfor restaurants and similar venues.It provides 4 AUX and 2 MIC inputs

Seite 3 - ADVANCED OUTPUT MODULES

ALL MODULESSOLD SEPARATELYAccessoriesFlexible Output LevelsThe VMIX was designed to make connec-tions to other sound system components aseasy as possi

Seite 4 - PUBLIC ADDRESS AMPLIFIERS

Product Features:• 8 independently assignable inputs• Dual-bus design with Main/AUX output selectorfor each input• Pluggable terminal strip connection

Seite 5 - UTILITY AMPLIFIERS

The CAM2 is a 5-input mixer/pre-amplifier suitable for a wide variety of applications, particularly for expanding the numberof inputs on Bogen or othe

Seite 6 - TELEPHONE PAGING AMPLIFIERS

BRIDGING INPUT - BRG1RDaisy Chain Multiple Amplifier Inputs• Gain/Trim control• Ground isolated input to eliminate ground loop• Input signal available

Seite 7 - DUAL-CHANNEL POWER AMPLIFIERS

AccessoriesRVCPRemote VolumeControl PanelAccessoriesANS500MSensor Microphone(One included; additional available)ComponentsBBFFlush-MountBack BoxBBSSur

Seite 8

Dual Band EQThe unique dual-function equalizer can beused for acoustic shaping or for feedbackcontrol.• Acoustic Shaping - Full range equaliza-tion is

Seite 9 - MONO-CHANNEL POWER AMPLIFIER

Utility AmplifierGA6AUtility AmplifierGA2Product Features:• 6-watt utility amplifier• 2 inputs: 1 MIC (Lo-Z), 1 AUX (Hi-Z)• 8-ohm, 25V, or 70V outputs

Seite 10 - PRO-MATRIX AMPLIFIER

AccessoriesSpecialized Telephone InputThe TPU-Series’ 600-ohm transformer bal-anced input is perfectly suited to connect topaging ports and paging ada

Seite 11 - MODULAR MIXER

Product Features:• Dual 70V amplifier channels• 300W, 450W, or 600W per channel for 70V speaker systems• Low noise, low distortion, and high slew rate

Seite 12 - MIC/LINE Mixer

Modular AmplifierThe M-Class Series of amplifiers are mod-ular amps that can accept up to two inputmodules per unit. These modules offer acost effecti

Seite 13 - CAM MIXERS SELECTION CHART

Product Features:• 125- and 250-watt models• Convection-cooled• Power MOSFET output circuitry• Thermal protection and automaticelectronic overload pro