Power Intercom SystemsModels PI35A & SI35AInstallation & Operation Guide
Basic System Hook-Up4-Wire Speaker Connections to the SBA2254-wire speaker connections (3-conductor + shield) is recommended for all new installations
Call-In SwitchesTwo call-in switches, CA10A and CA11A, are recommended for use with the SI and PI. The CA10A is a momen-tary push switch that has circ
Speakers and Speaker WiringThe MCP35A control panel of the SI and PI products is designed to use 25-volt distributed speakers. Thesespeakers have line
Advanced Hook-UpsExternal Emergency MicIt is possible to use a microphone (Model MBS1000) with a contact closure to make an emergency announce-ment. T
The Bogen model TAMB telephone interface module can be used to make a remote page through the telephonesystem.A Bogen TP-AP Series Interphone can be u
External Booster AmpAn external booster amplifier (Bogen Model BPA60) can be connected when the application requires more than35 watts. Using an exte
TWK351 Wire ConverterThe model TWK351 is an adapter used in instances where there is existing 3-wire (2-conductor + shield)room wiring. The TWK351 ca
SCR25A Call-In ModuleThe SCR25A module can be added to allow the annunciator indicators to light from a simple SPST call-in switch(Bogen model CA17).
SI35A Model Option EnhancementsThe SI35A has provisions to add up to 2 additional SBA225 switchbanks. Simply remove the blank panels andreplace with
Special AdjustmentsGain AdjustmentsScrewdriver-adjustable INPUT GAIN controls are located on the rear panel for MIC 1, MIC 2, AUX, TEL PAGE,TALK and L
© 1997 Bogen Communications, Inc.50 Spring St., Ramsey, NJ 07446All rights are reserved. No part of this document maybe photocopied, reproduced, or t
Internal Jumper SelectionsInternal jumpers are provided for phantom power (Mic1/Mic2), Telco Page/Mic 2 input selection, monitor speakermuting, and pr
Troubleshooting GuideMCP35A Troubleshooting ProcedureIf a problem exists on the MCP35A, certain steps should be taken to find the problem. This test
System SpecificationsRated Output:Program — 35W RMSIntercom — 20W RMSFrequency Response:Program — +1,-3dB from 80Hz to 15kHzIntercom — Shaped for maxi
50 Spring Street, Ramsey, NJ 07446, U.S.A.Tel: 201-934-8500 Fax: 201-934-9832web: www.bogen.com
ContentsUnpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Wiring & Grounding Precau
UnpackingYour Bogen equipment was carefully checked before leaving the factory; inspect the shipping container and unitclosely for improper handling.
IntroductionDescriptionBogen Models PI35A and SI35A are 25-station intercom systems (SI35A is expandable to 75 stations). Theycan provide facilities w
MCP35A Control Panel Front Panel1. CONSOLE MIC - Used as microphone 1 or in conjunction with the emergency page or press-to-talk/release-to-listen (in
MCP35A Control PanelRear View1. MIC 1 — Connections for an external mic (MIC 1). When the PROGRAM DISTRIBUTION button MIC 1 ispressed, the microphone
SBA225 Speaker Selector PanelFront View1. Room selector switch — Position of the room switch controls the type of audio program material deliveredto t
Basic System OperationCommunicating With a Selected SpeakerUse the following steps to talk and listen to a room that has its switch set to the “C” (do