Power Intercom SystemsModels PI35A & SI35AInstallation and Operation Manual© 2003 Bogen Communications, Inc.All rights reserved.Specifications sub
8Basic System Hook-Up4-Wire Speaker Connections to the SBA2254-wire speaker connections (3-conductor + shield) is recommended for all new installation
9Call-In SwitchesTwo call-in switches, CA10A and CA11A, are recommended for use with the SI and PI. The CA10A is a momen-tary push switch that has cir
10Speakers and Speaker WiringThe MCP35A control panel of the SI and PI products is designed to use 25-volt distributed speakers. These speakershave li
11Advanced Hook-UpsExternal Emergency MicIt is possible to use a microphone (Model MBS1000A) with a contact closure to make an emergency announce-ment
12The Bogen model TAMB2 Telephone Interface Module can be used to make a remote page through the telephonesystem.Note: Jumper J3 on the MCP35A printed
TWK351 Wire ConverterThe model TWK351 is an adapter used in instances where there is existing 3-wire (2-conductor + shield) roomwiring. The TWK351 ca
SCR25A Call-In ModuleThe SCR25A module can be added to allow the annunciator indicators to light from a simple SPST call-in switch(Bogen model CA17).
SI35A Model Option EnhancementsThe SI35A has provisions to add up to 2 additional SBA225 switchbanks. Simply remove the blank panels andreplace with
Special AdjustmentsGain AdjustmentsScrewdriver-adjustable INPUT GAIN controls are located on the rear panel for MIC 1, MIC 2, AUX, TEL PAGE,TALK and L
17Internal Jumper SelectionsInternal jumpers are provided for phantom power (MIC1/MIC2), Telco Page/MIC 2 input selection, monitor speak-er muting, an
NoticeEvery effort was made to ensure that the information in thisguide was complete and accurate at the time of printing.However, information is subj
Troubleshooting GuideMCP35A Troubleshooting ProcedureIf a problem exists on the MCP35A, certain steps should be taken to find the problem. This test r
System SpecificationsRated Output: Program – 35 WRMSIntercom – 20 WRMSFrequency Response: Program – +1, -3 dB from 80 Hz to 15 kHzIntercom – Shaped fo
Notes20
Notes21
50 Spring Street, Ramsey, NJ 07446, U.S.A.Tel. 201-934-8500 • Fax: 201-934-9832www.bogen.comThe Bogen PI35A & SI35A Power Intercom Systems are war
1ContentsUnpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Wiring &a
2UnpackingYour Bogen equipment was carefully checked before leaving the factory; inspect the shipping container and unitclosely for improper handling.
3IntroductionDescriptionBogen Models PI35A and SI35A are 25-station intercom systems (SI35A is expandable to 75 stations).They can provide facilities
4MCP35A Front Control Panel1234567891. CONSOLE MIC - Used as microphone 1 or in conjunction with the emergency page or press-to-talk/release-to-listen
5MCP35A Rear Control Panel1. MIC 1 - Connections for an external mic (MIC 1). When the PROGRAM DISTRIBUTION button MIC 1 ispressed, the microphone con
6SBA225 Speaker Selector Front Panel1. ROOM SELECTOR SWITCH - Position of the room switch controls the type of audio program material delivered to the
7Basic System OperationCommunicating With a Selected SpeakerUse the following steps to talk and listen to a room that has its switch set to the “C” (d